Brand:KSA200
Model:SODI
As the obviously brightness difference between inside and outside of the tunnel, because drivers will produce a variety of special vision problems when they are in and out of the tunnel, SODI light intensity detector can effectively reduce the effects of the brightness difference. SODI light intensity detector detects the light intensity inside and outside the tunnel, can effectively control the influence of tunnel lighting system, adjust the gateway and the lighting in the hole, ensure the safety of driving, and could satisfy the requirement of lighting in the circumstances to achieve the purpose of energy saving operation. Equipment can be installed in pairs, which means there can be one at outside of the tunnel entrance for detection of tunnel brightness, the other one installed inside of the tunnel for the detection of tunnel illumination.
Characteristics and Advantages:
In line with the international association of CIE for the special requirements of highway tunnel lighting control;
To ensure a stable output when low brightness signal;
Waterproof and dustproof design, can withstand the wild outdoor work under the bad environment;
With heating function;
The shell of IP68 protection ability.
Tunnel Illuminance Monitor:
Measuring range: 0~700cd/m2 (other range can be customized)
Measuring Angle: Vertical Angle≥30°, Horizontal Angle≥40°
Measuring accuracy: ≤±1cd/m2
Error value: ≤1%
Values repeatability: ≤0.1%
Spectral response error: ≤1%
Analog output: 4 ~ 20 mA
Switch output: three groups of 1 a/250V relay output
Performance Measures:
Load resistance: ≤1000Ω
Output interface, RS232 and RS422
Working temperature: - 50 ℃ ~ 80 ℃
Work humidity: 0%~100%
Protection level: IP68
Working power supply: AC76-250V 50Hz 10W+20W (heating)
Weight:
1.5 kg (KSA200);
Custom Function:
The local data storage;
Measurements are LED real-time display;
Digital output function
Installation Advice:
The installation height of installation:
In order to avoid the highway vehicle apparatus and prevent the loss of detector, installation height of about 3-4 m;
Installation location:
Tunnel Vision Luminance & Illumination Meter is generally installed from the tunnel mouth of the 50-200 meters; Tunnel Illuminance Monitor is apart from the mouth of the hole 50-150 meters; Specifically according to the situation on site and determine the installation position;
Installation type:
Upright type or metope type.