Tunnel Air Quality Monitor (NO、CO)

Tunnel Air Quality Monitor (NO、CO)

Brand:SODI

Model:CVD-NO

Product Description

SODI CO/VI/NO detector is specially used for highway tunnel environment monitoring, which detect the carbon monoxide, nitric oxide concentration and coefficient of visibility, it can maintain the all-weather real-time detection of tunnel CO/NO concentration coefficient and visibility. After testing data processing to the tunnel management computer system with monitoring system analysis, so as to timely put forward the best monitoring and tunnel ventilation fan operating plan. CO/VI/NO detector should have very strong self-checking function, CO/VI/NO real-time online monitoring the working state of the detector, when its failure to operate, it will be alarmed immediately .


Characteristics and Advantages:

1. Flexible configuration, carbon monoxide, nitric oxide, visibility range can be arbitrary configuration and unit, etc.;

2. Installation is simple - the only connection mouth;

3. Interface variety - 4~20mA or 0~20mA,RS232 interface, relay interface, etc.;

4. High reliability - as long as a moving parts, testing operation, reliable and continuous surface maintenance design;

5. High precision - rapid, accurate, continuous automatic determination of co concentration, nitric oxide, transmittance parameters, leading the market of patented technology;

6. Custom function - measuring values led real-time display function, can expand the function of nitrogen oxide


Technical Indicators:

Carbon monoxide (CO)

NO Detector

Visibility (VI or transmittance)

Scope: 0~400ppm(measuring range adjustable)  ;

Scope: 0~300ppm (measuring range adjustable)  ;

Scope: 0~0.035/m(measuring range adjustable);

Accuracy:±1ppm  ;

Accuracy:±1ppm  ;

Accuracy:±0.001/m or 0.7%light transmittance;

Resolution: 0.1ppm;

Response time: 

0.1 seconds to 60 min(adjustable);

Response time: 

0.1 seconds to 60 min (adjustable);

Response time: 

0.1 seconds to 60 minutes (adjustable);

Range spectrum: 

infrared laser induction method;

Quantity of the spectrum::visible light

Range spectrum: 

infrared laser induction method;


Optical path: 

3 m, or 10 meters single photon processes

Optical path: 

3 m, or 10 meters single photon processes





Performance Measures: 

  • Analog output: 4 ~ 20 mA output corresponding isolation CO value, VI value, NO value; CO, VI, NO transfinite alarm or fault alarm.

  • Digital output: Passive relay output can be set up corresponding CO, VI, NO transfinite alarm or fault alarm.

  • Serial communication: RS485 and RS232, support wireless transmission mode.

  • The ac power: 100 ~ 240 VAC. 50 Hz.

  • Protection grade: IP68;

  • The input voltage: 76 ~ 265 VAC.

  • Maximum load: 1000 Ω;

  • Working temperature: -80℃~+80℃;

  • Working humidity: 0%~100%RH;


Installation Method:

CO/VI/NO probe. CO/VI/NO detector installed in the tunnel driving directions on the right side wall, the hanging installation, should not encroach on the road the following clearance within 5 m.


Materials:

Ontology sturdy plastic spraying aluminum alloy surface treatment, high strength and preservative coating, and through rigorous testing, corrosion protection and electromagnetic leakage protection, automatic constant temperature heating optical lens, dew, drip-proof, moisture-proof, dustproof design.


Weight:

Transmitter: 5.7 KG;

Receiver: 5.5 KG;

Stents (single) : 2.5 KG