SODI ELECTRONICS
English Italian

Tunnel Air Quality Monitor (CO)

Tunnel Air Quality Monitor (CO)

Brand:SODI

Model:CVD

Product Description

SODI COVI detector is specially used for highway tunnel environment monitoring, carbon monoxide concentration can detect coefficient of visibility to keep the all-weather real-time detection of tunnel coefficient of CO concentration and visibility. To achieve energy saving operation and keep the fan operates with better life; according to different locations, in the event of a fire, the corresponding fire smoke extraction processing ensure the safety of the tunnel and operating environment of comfort. Its professional tunnel design is perfectly using high precision technology, completely avoid the environment problems such as the impact on the equipment, and available to make the equipment under harsh conditions of a continuous and reliable operation.


Characteristics and Advantages:

1. Flexible configuration, carbon monoxide, visibility range can be arbitrary configuration and unit, etc.;

2. Installation is simple - the only connection mouth;

3. Interface variety - 4 ~ 20 mA, or 0 to 20 mA, RS232 interface, relay interface, etc.;

4. High reliability - as long as a moving parts, testing operation, reliable and continuous surface maintenance design;

5. High precision - rapid, accurate, continuous automatic determination of co concentration, transmittance parameters, leading the market of patented technology;

6. Custom function - measuring values led real-time display function, can expand the function of nitrogen oxide


Technical Indicators:

Carbon monoxide (CO)

Visibility (VI or transmittance)

Scope: 0~400ppm(measuring range adjustable)  ;

Scope: 0~0.035/m(measuring range adjustable);

Accuracy:±1ppm  ;

Accuracy:±0.001/m or 0.7% light transmittance;

Resolution: 0.1ppm;

Response time: 0.1 seconds to 60 minutes (adjustable);

Response time: 0.1 seconds to 60 minutes (adjustable);

Quantity of the spectrum::visible light

Range spectrum: infrared laser induction method;

Optical path: 3 m, or 10 meters single photon processes

Optical path: 3 m, or 10 meters single photon processes


 

Performance Measures: 

  • Working power supply: 76~265VAC

  • Load resistance: 1000Ω

  • Work temperature: -50℃~+80℃

  • Work humidity: 0%~100%RH

  • Protection grade: IP68


Output:

  • A serial port output: RS485/232/422 / CAN data bus;

  • Analog output: 2 groups 0-10V (isolated output); 2 groups 0/2/4-20mA (isolated output);

  • Digital output: Programmable limit alarm relay; Programmable alarm relay maintenance;


Materials:

Ontology sturdy plastic spraying aluminum alloy surface treatment, high strength and preservative coating, and through rigorous testing, corrosion protection and electromagnetic leakage protection, automatic constant temperature heating optical lens, dew, drip-proof, moisture-proof, dustproof design


Weight:

Transmitter: 5.7 KG;

Receiver: 5.5 KG;

Stents (single) : 2.5 KG


Customization: 

Numerical measurement LED real-time display function;

Extensible function of nitrogen oxide.